b53: Allow using all 8 ports on BCM53011
authorrmilecki <rmilecki@3c298f89-4303-0410-b956-a3cf2f4a3e73>
Mon, 22 Jun 2015 07:59:09 +0000 (07:59 +0000)
committerrmilecki <rmilecki@3c298f89-4303-0410-b956-a3cf2f4a3e73>
Mon, 22 Jun 2015 07:59:09 +0000 (07:59 +0000)
commit45af270042373818324b9ed5b57cd77bede6cbf6
tree8d1e96a9890656ab0fd780baa58c6dee4321c706
parent9e495194de1b2e6bb9bd6a79dbbe687b318f5259
b53: Allow using all 8 ports on BCM53011

On two tested devices: Netgear R6250 (BCM53011 rev 2) and Luxul XWC-1000
(BCM53011 rev 3) it was possible to use port 7 and eth1 (instead of port
5 and eth0). It seems BCM53011 just like BCM53012 has 8 ports and
usually 3 of them are connected to the SoC.

Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
Backport of r46104

git-svn-id: svn://svn.openwrt.org/openwrt/branches/chaos_calmer@46107 3c298f89-4303-0410-b956-a3cf2f4a3e73
target/linux/generic/files/drivers/net/phy/b53/b53_common.c