rb532: check the link status with a timer
[10.03/openwrt.git] / target / linux / rb532 / patches-2.6.28 / 005-pata_rb532_cf_4bytes_rw.patch
1 * rename the offset definition to avoid abiguity with the standard ATA
2   IO address
3 * read and write four bytes at once like the original driver does
4 * use writesl() and readsl() which implicitly iterate over the data
5
6 This patch assumes buflen to be a multiple of four, which is true for
7 ATA devices. ATAPI support is not known, though unlikely, as the
8 original driver always transfers 512 Bytes at once.
9
10 Signed-off-by: Phil Sutter <n0-1@freewrt.org>
11 Acked-by: Sergei Shtyltov <sshtylyov@ru.mvista.com>
12 ---
13 --- a/drivers/ata/pata_rb532_cf.c
14 +++ b/drivers/ata/pata_rb532_cf.c
15 @@ -82,13 +82,10 @@ static unsigned int rb532_pata_data_xfer
16         void __iomem *ioaddr = ap->ioaddr.data_addr;
17         int retlen = buflen;
18  
19 -       if (write_data) {
20 -               for (; buflen > 0; buflen--, buf++)
21 -                       writeb(*buf, ioaddr);
22 -       } else {
23 -               for (; buflen > 0; buflen--, buf++)
24 -                       *buf = readb(ioaddr);
25 -       }
26 +       if (write_data)
27 +               writesl(ioaddr, buf, buflen / sizeof(u32));
28 +       else
29 +               readsl(ioaddr, buf, buflen / sizeof(u32));
30  
31         rb532_pata_finish_io(adev->link->ap);
32         return retlen;