luci2: cleanup system.upgrade view markup, remove leftover call to jquery-ui tabs()
[project/luci2/ui.git] / luci2 / htdocs / luci2 / template / system.upgrade.htm
index 6541c22..e9b8d3a 100644 (file)
@@ -1,39 +1,51 @@
-<div class="cbi-form" id="tabs" style="display:none">
-       <ul class="cbi-tabmenu">
-               <li><a href="#actions"><%:Actions%></a></li>
-               <li><a href="#config"><%:Configuration%></a></li>
-       </ul>
+<ul class="nav nav-tabs">
+       <li class="active"><a data-toggle="tab" href="#actions"><%:Actions%></a></li>
+       <li><a data-toggle="tab" href="#config"><%:Configuration%></a></li>
+</ul>
 
 
-       <div id="actions">
-               <h3><%:Backup / Restore%></h3>
-               <p><%:Click "Generate archive" to download a tar archive of the current configuration files. To reset the firmware to its initial state, click "Perform reset" (only possible with squashfs images).%></p>
-               <p>
-                       <form action="/cgi-bin/luci-backup" method="post" style="display:inline">
-                               <input type="hidden" name="sessionid" />
-                               <input class="cbi-button cbi-button-apply" type="button" id="btn_backup" value="<%:Generate archive%>" />
-                       </form>
-                       <input class="cbi-button cbi-button-reset" type="button" id="btn_reset" value="<%:Perform reset%>" />
-               </p>
-               <br />
+<div class="tab-content">
+       <div class="tab-pane active" id="actions">
+               <div class="panel panel-default">
+                       <div class="panel-heading">
+                               <h3 class="panel-title"><%:Backup / Restore%></h3>
+                       </div>
+                       <div class="panel-body">
+                               <p><%:Click "Generate archive" to download a tar archive of the current configuration files. To reset the firmware to its initial state, click "Perform reset" (only possible with squashfs images).%></p>
+                               <p>
+                                       <form action="/cgi-bin/luci-backup" method="post" style="display:inline">
+                                               <input type="hidden" name="sessionid" />
+                                               <input class="btn btn-primary" type="button" id="btn_backup" value="<%:Generate archive%>" />
+                                       </form>
+                                       <input class="btn btn-danger" type="button" id="btn_reset" value="<%:Perform reset%>" />
+                               </p>
 
 
-               <p><%:To restore configuration files, you can upload a previously generated backup archive here.%></p>
-               <p>
-                       <input class="cbi-button cbi-input-apply" type="button" id="btn_restore" value="<%:Upload archive...%>" />
-               </p>
-               <br />
+                               <p><%:To restore configuration files, you can upload a previously generated backup archive here.%></p>
+                               <p>
+                                       <input class="btn btn-primary" type="button" id="btn_restore" value="<%:Upload archive...%>" />
+                               </p>
+                       </div>
+               </div>
 
 
-               <h3><%:Flash new firmware image%></h3>
-               <p><%:Upload a sysupgrade-compatible image here to replace the running firmware. Check "Keep settings" to retain the current configuration (requires an OpenWrt compatible firmware image).%></p>
-               <p>
-                       <input class="cbi-button cbi-input-apply" type="button" id="btn_flash" value="<%:Flash image...%>" />
-               </p>
+               <div class="panel panel-default">
+                       <div class="panel-heading">
+                               <h3 class="panel-title"><%:Flash new firmware image%></h3>
+                       </div>
+                       <div class="panel-body">
+                               <p><%:Upload a sysupgrade-compatible image here to replace the running firmware. Check "Keep settings" to retain the current configuration (requires an OpenWrt compatible firmware image).%></p>
+                               <p>
+                                       <input class="btn btn-primary" type="button" id="btn_flash" value="<%:Flash image...%>" />
+                               </p>
+                       </div>
+               </div>
        </div>
 
        </div>
 
-       <div id="config">
-               <textarea style="width:100%"></textarea>
-               <div class="cbi-page-actions">
-                       <input class="cbi-button cbi-button-save" type="button" id="btn_save" value="<%:Save%>" />
-                       <input class="cbi-button cbi-button-apply" type="button" id="btn_list" value="<%:Show current backup file list …%>" />
+       <div class="tab-pane" id="config">
+               <div class="panel">
+                       <textarea class="form-control"></textarea>
+               </div>
+               <div class="pull-right">
+                       <input class="btn btn-primary" type="button" id="btn_save" value="<%:Save%>" />
+                       <input class="btn btn-default" type="button" id="btn_list" value="<%:Show current backup file list …%>" />
                </div>
        </div>
 </div>
                </div>
        </div>
 </div>