luci-app-mwan3: pin diag ping command to interface device 1787/head
authorFlorian Eckert <fe@dev.tdt.de>
Wed, 9 May 2018 11:48:27 +0000 (13:48 +0200)
committerFlorian Eckert <fe@dev.tdt.de>
Wed, 9 May 2018 12:20:03 +0000 (14:20 +0200)
If the physical device is not set in the diag_command then the ping will
always use the route with the lowest metric from the default routing
table.
To fix this add the physical device of the logical interface to the ping
command.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
applications/luci-app-mwan3/luasrc/controller/mwan3.lua

index 01e40d9..18c2135 100644 (file)
@@ -97,9 +97,9 @@ function diagnosticsData(interface, task)
                return interfaceNumber
        end
 
-       function diag_command(cmd, addr)
+       function diag_command(cmd, device, addr)
                if addr and addr:match("^[a-zA-Z0-9%-%.:_]+$") then
-                       local util = io.popen(cmd % ut.shellquote(addr))
+                       local util = io.popen(cmd %{ut.shellquote(device), ut.shellquote(addr)})
                        if util then
                                while true do
                                        local ln = util:read("*l")
@@ -145,7 +145,7 @@ function diagnosticsData(interface, task)
                if task == "ping_gateway" then
                        local gateway = get_gateway(interface)
                        if gateway ~= nil then
-                               diag_command("ping -c 5 -W 1 %s 2>&1", gateway)
+                               diag_command("ping -I %s -c 5 -W 1 %s 2>&1", device, gateway)
                        else
                                luci.http.prepare_content("text/plain")
                                luci.http.write(string.format("No gateway for interface %s found.", interface))
@@ -154,7 +154,7 @@ function diagnosticsData(interface, task)
                        local trackips = uci:get("mwan3", interface, "track_ip")
                        if #trackips > 0 then
                                for i in pairs(trackips) do
-                                       diag_command("ping -c 5 -W 1 %s 2>&1", trackips[i])
+                                       diag_command("ping -I %s -c 5 -W 1 %s 2>&1", device, trackips[i])
                                end
                        else
                                luci.http.write(string.format("No tracking Hosts for interface %s defined.", interface))