b53: Allow using all 8 ports on BCM53011
authorrmilecki <rmilecki@3c298f89-4303-0410-b956-a3cf2f4a3e73>
Mon, 22 Jun 2015 07:59:09 +0000 (07:59 +0000)
committerrmilecki <rmilecki@3c298f89-4303-0410-b956-a3cf2f4a3e73>
Mon, 22 Jun 2015 07:59:09 +0000 (07:59 +0000)
On two tested devices: Netgear R6250 (BCM53011 rev 2) and Luxul XWC-1000
(BCM53011 rev 3) it was possible to use port 7 and eth1 (instead of port
5 and eth0). It seems BCM53011 just like BCM53012 has 8 ports and
usually 3 of them are connected to the SoC.

Signed-off-by: Rafał Miłecki <zajec5@gmail.com>
Backport of r46104

git-svn-id: svn://svn.openwrt.org/openwrt/branches/chaos_calmer@46107 3c298f89-4303-0410-b956-a3cf2f4a3e73

target/linux/generic/files/drivers/net/phy/b53/b53_common.c

index 47b5a8b..859d8d1 100644 (file)
@@ -1201,7 +1201,7 @@ static const struct b53_chip_data b53_switch_chips[] = {
                .dev_name = "BCM53011",
                .alias = "bcm53011",
                .vlans = 4096,
-               .enabled_ports = 0x1f,
+               .enabled_ports = 0x1bf,
                .cpu_port = B53_CPU_PORT_25, /* TODO: auto detect */
                .vta_regs = B53_VTA_REGS,
                .duplex_reg = B53_DUPLEX_STAT_GE,